Bosch Rexroth OptiFeed-FS EcoDrive 03 FLP04VRS Functional Description page 295

With integrated nc control
Table of Contents

Advertisement

ECODRIVE03-FL*-04VRS
System Marker Flags (Outputs)
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
M0.01
All bits in this byte are reserved.
M0.02
These marker flags are only valid if the function is enabled in the
designated parameter.
Status of the Function Inputs
Bit
Function
0
Interrupt
1
Feed Angle Monitoring
2
Manual Vector
3
Interrupt vector
4
Reserved (Free)
Restart
5
Reserved (Free)
elektrisches Lüften
6
Reserved (Free)
Motorbremse lüften
7
Measuring Wheel Control enabled
Fig. 10-8: Marker Flags - Programmable System Inputs
Note:
If the functions for bits 0 and 1 are not set in the parameters,
these bits are initialized by setting them to '1.'
M0.03
All bits in this byte are reserved.
M0.04
All bits in this byte are reserved.
M0.05
All bits in this byte are reserved.
Here, the conditions are mirrored.
These marker flags are read-only using the Logic Task and the NC Task.
M1.00
Bit
Function
0
Manual Mode
1
Automatic
2
Fault
3
Run
4
Ready
5
Warning
6
Parameter
7
In Position (Switching Threshold)
Fig. 10-9: Marker Flags - System Outputs
10-11
Interface
Source
Parameter A116
Parameter A116
Parameter AA01
Parameter AA02
Parameter AA07
Source
Status
Status
Status
Status
Status
Status
Status