F296 Number Of Ecox Slaves Incorrect; F297 Error In Ecox Slave; F386 No Ready Signal From Supply Module - Bosch Rexroth OptiFeed-FS EcoDrive 03 FLP04VRS Functional Description

With integrated nc control
Table of Contents

Advertisement

ECODRIVE03-FL*-04VRS

F296 Number of EcoX Slaves incorrect

F297 Error in EcoX Slave

F386 No ready signal from supply module

DOK-ECODR3-FL*-04VRS**-FK01-EN-P
In Parameter B014, EMD Configuration the number of EcoX slaves has
to be entered. If the master notices that the number of EcoX slaves does
not correspond with the parameterized value when scanning the slaves,
warning E296 Number of EcoX slaves incorrect is generated.
The EcoX master cyclically scans the EcoX slaves until their number
corresponds with the parameterized number of EcoX slaves. If warning
E296 is activated and you try to set the controller enable signal, error
F296 is generated.
Cause:
1. The EcoX bus has not been correctly wired
2. The EcoX bus has not been parameterized in an EcoX slave
and/or master
3. The EcoX bus is disturbed
4. The supply voltage of the EcoX slaves was cut off
Remedy:
1. Check the wiring of the EcoX bus
2. Check parameterization
3. Check the EcoX bus
4. Check supply voltage of the EMD modules
If an error (e. g. F292 Overtemperature in EMD module) occurs in an
EcoX slave, this is communicated to the EcoX master via the EcoX
interface. Error F297 is then generated in the EcoX master.
Cause:
An error occurred in an EcoX slave.
Remedy:
Remedy the cause of the error in the EcoX slave. Then delete the
error message in the EcoX slave and in the EcoX master.
Cause:
Input BbN "Power supply ready" on the drive controller is at 24V, i.e., the
connected power supply is not issuing a ready signal.
Diagnostic Message Descriptions