14.3 User Interface; Introduction - Bosch Rexroth OptiFeed-FS EcoDrive 03 FLP04VRS Functional Description

With integrated nc control
Table of Contents

Advertisement

ECODRIVE03-FL*-04VRS

14.3 User Interface

Introduction

DOK-ECODR3-FL*-04VRS**-FK01-EN-P
Using the TXT command, one simple user screen/interface can be
created in the NC program.
To do this, the BTV04 hardware with the BTV04-ELC-01V08 firmware or
higher is required.
Example:
M a n u a l
M A I N - M E N U
M A C H I N E
A C T P O S :
+ 0 0 0 0 0 1 2 3 . 1 2 3
L E N G T H :
0 0 0 1 . 0 0 0
V E L O C I T Y :
P I E C E S :
Fig. 14-5: Text
On each line, text or variable contents can be displayed, and variable
contents can be edited.
The NC lines are used as display specifications, beginning with NC
instruction 500 (default setting). This start instruction number can be
edited in "Start Adr Text" (see Special Displays). Up to 6 different display
specifications can be written. In the user interface, the displays are called
up by pressing function keys F1 - F6.
The TXT 0 command is used as an identifier for the display specification.
The NC instructions are read in sequence, until another command is
reached.
Note:
For any erroneous entries in the format specification, the data
is erroneously displayed, or not displayed at all.
Note:
The specifications are processed in the order in which they
were programmed. The following definitions can overwrite
other definitions on the display!
Note:
Variables must be programmed for the associated NC
program.
.
Status Line
Line 1
Line 2
2 3 4 5
Line 3
Line 4
MM
Line 5
9 9 9
0 0 0 0
Line 6
14-17
Display