Bosch Rexroth OptiFeed-FS EcoDrive 03 FLP04VRS Functional Description page 329

With integrated nc control
Table of Contents

Advertisement

ECODRIVE03-FL*-04VRS
Write Saved Marker Flags:
Change a Bit in Marker Flag
Group M8:
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
Change a byte from a saved marker flag group.
Format:
! s C S E T M B _ M g . n n _ x x x x x x x x _ $ h h CR LF
With g: Marker Flag Group (3, 6 or 8)
Note:
For marker flag groups M3 and M6, the command is accepted
only in Parameter Mode.
Note:
There is no time monitoring of the data transmission!.
The marker flags are saved.
A Yes response follows, and the command is successfully completed.
Change a bit in marker flag group M8.
! s C S E T M _ M 8 . n n . b _ x _ $ h h CR LF
With
Note:
There is no time monitoring of the data transmission!.
The marker flags are saved.
A Yes response follows, and the command is successfully completed.
Bit7
Bit0
nn : Byte Number 00 to 19 (depending on group)
x: 0 = Clear bit
1 = Set bit
2 = Leave bit unchanged
3 = Invert bit
nn : Byte number 00 to 19
b: Bit number of the selected byte.
x: 0 = Clear bit
1 = Set bit
2 = Leave bit unchanged
3 = Invert bit
10-45