B011 Fieldbus Cycle Time

B012 Fieldbus Baudrate

DOK-ECODR3-FL*-04VRS**-FK01-EN-P
Valid only for DKC3.3 with Profibus
05000
Maximum Cycle Time [ms]
Cyclic transmission of the process data via the fieldbus is monitored. If no
new message is received within the maximum cycle time, the control unit
generates one of the following warning or error messages:
"E- 01 04 – No Systemctrl."
"F- 03 16 – Systemctrl. Error"
"F- 03 17 – User I/O Error"
The "E- 01 04" warning is generated whenever communication takes
place via the fieldbus and the control unit is in Parameter Mode. The
"F-03 16" error message is generated whenever communication takes
place via the fieldbus and the control unit is in Manual or Automatic Mode.
The "F- 03 17" error message is generated whenever communication
does not take place via the fieldbus and the control unit is in Automatic
Mode.
If the cycle time is predetermined by the fieldbus master, the actually used
value is written to this parameter and can be read out for diagnostic
purposes.
Note:
A value of 0 means that monitoring is turned off!
For further information, see the Profibus Command Communication
chapter.
Valid only for DKC3.3 with Profibus
000019.2
Baud Rate [kBaud]
Here, the desired baud rate in increments of 1 kBaud can be set, if the
fieldbus does not automatically detect the baud rate. If the set baud rate is
not allowed, a default baud rate for the particular fieldbus is used. The
actually used value is written to this parameter and can be read out for
diagnostic purposes.
For further information, see Section: Profibus Command Communication.
9-41