Bosch Rexroth OptiFeed-FS EcoDrive 03 FLP04VRS Functional Description page 321

With integrated nc control
Table of Contents

Advertisement

ECODRIVE03-FL*-04VRS
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
Status 19
Hardware and firmware version
The status query:
? s X _ _ 1 9 _ C R L F
produces the following message, e.g.,:
X s 1 9 D K C 2 1 . 3 _ _ _ _ _ _ _ _ _ E C O D R 3 - F L P - x x V x x $ h h C R L F
Status 25
Two-digit diagnostic code with text output
see also TXT Command, Markers M6.37 – M6.39 and
Functional Description for 'Logic Task Controlled Diagnostic for Status
Message 25.'
The status query:
? s X _ _ 2 5 _ C R L F
produces the message:
Xs25_cc--------40 characters information-----$hh C R L F
cc = Current diagnostic code
Examples:
Xs25_8BAxis 1 Motor Has Overheated
Xs25_02M: Feed Forward
Overview of Error Messages:
Status Messages:
"02M: Feed Forward
"0EPARAMETER MODE
"17M: Feed Reverse
"18Initializing System
"1AA: C.Stop Active
"3AFeed Rolls Open
"48Stop Due To Interrupt Input!
"99Control Error, See H1 Display
Minor Error:
"13 Both Jogs High
10-37
Interface
Firmware version
max. 16 characters
Hardware version
max. 16 characters
$hh CR LF
$hh CR LF
"
"
"
"
"
"
"
"
"

Advertisement