12.9 NC- Status Diagnostics A- .. ..

A- 0007 Stop is active

A- 0008 Manual vector program is active

A- 0009 Function interrupt is active

A- 0011 Feed rolls open

A- 0012 Press Timeout

A- 0013 Waiting for Feed Angle

A- 0026 Control signal bit 1 invalid

A- 0027 Control signal bit 2 invalid

DOK-ECODR3-FL*-04VRS**-FK01-EN-P
No voltage at the Stop input X210/4 or the automatic program was
stopped using a Stop command (JST).
The Manual Vector program in Parameter AA01 is currently being
processed.
24V not present at input programmed in Parameter A116.
In Parameters AA05 and AA06, the function 'Open feed rolls' was
activated and the output for opening the feed rolls is currently active,
based on the PLS position or the input state.
In Parameter AA19, press monitoring is active. No signal change for the
feed area (Parameter A116) occurred during the set time (Parameter
AA19).
The signal at input 'Feed angle monitoring' (feed angle) is not present.
See Parameter A116.
The function was activated in Parameters AA14 and AA15, to compare
PLS positions with a particular state of an input signal. The state of the
input signal from Parameter AA15 did not correspond to the PLS position.
Check input signal and PLSs.
The function was activated in Parameters AA14 and AA16, to compare
PLS positions with a particular state of an input signal. The state of the
input signal from Parameter AA16 did not correspond to the PLS position.
Check input signal and PLSs.