Parameters

Online Changeable Parameters

Input Unit

Changeable Parameters
A110
AA15 ... AA18
B006 ... B008
CRxx
Conditionally Changeable Parameters
Can be changed, if no SA1 command is active in the program:
B003 ... B005
Can be changed, if no program is running:
C019
The following parameters should only be changed at idle PLS encoder in
Manual Mode. Each modification will cause a dead time of 10ms in which
the outputs of the PLS stay unchanged.
N111 ... N118
N121 ... N131
The input unit is defined in Parameter A101 Feed Constant. The feed
constant is defined as the linear displacement of the load during one
revolution of the gear output shaft. Input can be in any desired dimension
and is referred to below as the input unit (IU).
It is important that all other measurements entered be referenced to this
same unit.
e.g.
IU [mm]
In this case, the velocity is entered or shown as IU/s,
hence mm/s.
IU [inch]
In this case, the velocity in entered or shown as IU/s,
hence inches/s.
ECODRIVE03-FL*-04VRS
Bipolar Jerk Limiting Time Constant
Signal Controlbit 1 ... 4
Analog Output 2
All Controller Parameters
Analog Output 1
SSI Encoder Reference Distance
Function of Output Channel 1
Switch 1
DOK-ECODR3-FL*-04VRS**-FK01-EN-P