Logic Task - Bosch Rexroth OptiFeed-FS EcoDrive 03 FLP04VRS Functional Description

With integrated nc control
Table of Contents

Advertisement

10-30
Interface

Logic Task

Read Out Logic Task
Write Logic Task
Logic Task instructions can be read out in any operating mode.
Format:
? s P x x x x _ $ h h C R L F
In response to this query, the contents stored in the queried Logic Task
instruction 'xxxx' is sent.
P s x x x x _ b b b b b _ d d d d d d d _ $ h h C R L F
Meaning of the characters used:
x = Instruction number
b = Logic task assignment
d = Operand (Length up to 7 characters)
Writing Logic Task instructions is only possible in 'Parameter' Mode !
Format:
# s P x x x x _ b b b b b _ d d d d d d d _ $ h h C R L F
Meaning of the characters used:
x = Instruction number
b = Logic task assignment
d = Operand (Length up to 7 characters)
Command Data
LD
LD_ _ _ _M2.02.0_
LDN
LDN_ _ _M2.02.0_
ST
ST_ _ _ _M2.02.0_
STN
STN_ _ _M2.02.0_
S
S _ _ _ _ _M2.02.0_
SET
SET _ _ _M2.02.0_
SETC
SETC _ _M2.02.0_
SETCN
SETCN _M2.02.0_
R
R_ _ _ _ _M2.02.0_
RES
RES_ _ _M2.02.0_
RESC
RESC_ _M2.02.0_
RESCN
RESCN _M2.02.0_
AND
AND _ _ _M2.02.0_
ANDN
ANDN _ _M2.02.0_
AND(
AND( _ _M2.02.0_
ANDN(
ANDN( _M2.02.0_
OR
OR_ _ _ _M2.02.0_
ORN
ORN_ _ _M2.02.0_
OR(
OR( _ _ _M2.02.0_
ORN(
ORN( _ _M2.02.0_
XOR
XOR_ _ _M2.02.0_
XORN
XORN_ _M2.02.0_
XOR(
XOR( _ _M2.02.0_
XORN(
XORN( _M2.02.0_
)
)_ _ _ _ _
NOP
NOP_ _ _
END
END_ _ _
ECODRIVE03-FL*-04VRS
DOK-ECODR3-FL*-04VRS**-FK01-EN-P

Advertisement

Table of Contents
loading

Table of Contents