12-38
Diagnostic Message Descriptions
C228 Wrong controller type
C234 Encoder combination not possible
C235 Load-side motor encoder with inductance motor only
C300 Set absolute measuring
C301 Setting absolute encoder not possible when RF set
In preparing for the communications Phase 4 transition check, first check
whether the heat-sink temperature model data stored in the resident
memory of the amplifier are valid. If an error is detected, the drive
responds with the error message C228 Wrong controller type.
Cause:
Amplifier EEPROM defective.
Remedy:
Replace/repair controller.
Cause:
The encoder interface that has been selected in Parameter C004,
Interface feedback 2, cannot be supported by the drive; since it has
already been allocated to the motor encoder.
Remedy:
Select another optional encoder.
Cause:
The functionality of the optional encoder can be defined in Parameter
A100, Type of application. If 'load-side motor encoder' has been
selected as the function of the optional encoder, that function will be
supported only for asynchronous motors.
Remedy:
Set Parameter CM00, Motor type in accordance with the type of motor
used.
Check Parameter A100, Type of application.
The Set absolute encoder function was activated via Parameter C010,
Homing.
"C3" Display
Cause:
The "C3 Command, set absolute encoder emulator" was initiated in
response to the current drive enable signal.
Remedy:
Terminate the command and deactivate the drive enable signal.