8-24
Functions
Slave Axis
The axis follows the positions pre-set by the master axis encoder exactly.
With the FOL command, this function can be turned on or off. In addition,
a gear can be edited with this command, even during operation, by
changing a factor value. Dynamic synchronization (acceleration or
deceleration) is possible.
The activation of this function occurs in the user program with the FOL
command.
See also Section 6, 'NC Commands.'