C015 Encoder Emulation Resolution; C016 Marker Pulse Offset - Bosch Rexroth OptiFeed-FS EcoDrive 03 FLP04VRS Functional Description

With integrated nc control
Table of Contents

Advertisement

9-50
Parameters

C015 Encoder Emulation Resolution

C016 Marker Pulse Offset

02500
Resolution: For incremental encoder emulation up to
If incremental encoder emulation is selected as the actual position output,
the number of graduation marks used by the emulated incremental
encoder must be entered here.
See also functional description for: "Encoder Emulation."
Input min.:
1
Input max.:
65536 or
000.0
Offset in Degrees
For the emulated incremental encoder, this parameter can shift the
position of the marker pulse (zero pulse) within one (electrical or
mechanical) revolution.
See also functional description for: "Encoder Emulation."
Input min.:
0
Input max.:
359.9
ECODRIVE03-FL*-04VRS
65536
For absolute encoder emulation 8 – 24
bits
or
8
24
DOK-ECODR3-FL*-04VRS**-FK01-EN-P