Interface; 10.1 Inputs / Outputs / Marker Flags - Bosch Rexroth OptiFeed-FS EcoDrive 03 FLP04VRS Functional Description

With integrated nc control
Table of Contents

Advertisement

ECODRIVE03-FL*-04VRS
10

Interface

10.1 Inputs / Outputs / Marker Flags

DOK-ECODR3-FL*-04VRS**-FK01-EN-P
Designation
The designation of the inputs, outputs and marker flags.
M = Marker Flag
I = Input
Q = Output
Fig. 10-1: Structure of the Inputs / Outputs / Marker Flags
e.g.
I0.00.6
I
Input
I0
Input, Connector X210
I0.00
Input, Connector X210, Group 0 (Byte 00)
I0.00.6 Input, Connector X210, Group 0 (Byte 00, Bit 6)
First user-programmable input
Inputs
The inputs are designated with 'I.' They can be programmed and
processed in the parameters, commands, and in the Logic Task. They
are read at the beginning of each cycle (every 2 ms) or at the start of the
Logic Task.
Source
Bytes
0
00...01
1
00...04
2
00...05
3
00...03
4
00. .01
Fig. 10-2: Source Numbers of the Inputs
M2.02.0
Bit
Byte
Source
Functions
DSUB Connector X210
DKC21.3
BTV04 (can be enabled via Parameter B009 / B010)
Fieldbus : Profibus DKC3.3
EMD Enhancement
Hardware Inputs X1, X3
10-1