ECODRIVE03-FL*-04VRS
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
Variables
Definition
520
<V500> + <V508> * <V509>
521
<V501> + <V508> * <V509>
522
<V502> + <V508> * <V509>
523
<V503> + <V508> * <V509>
524
<V504> + <V508> * <V509>
525
<V505> + <V508> * <V509>
526
<V506> + <V508> * <V509>
527
<V507> + <V508> * <V509>
528
508
529
509
Fig. 6-7: Variable Block 1: Contents of the indexed variables with actual Offset
Factor V508 and actual Index V509
Variables
Definition
530
<V510> + <V518> * <V519>
531
<V511> + <V518> * <V519>
532
<V512> + <V518> * <V519>
533
<V513> + <V518> * <V519>
534
<V514> + <V518> * <V519>
535
<V515> + <V518> * <V519>
536
<V516> + <V518> * <V519>
537
<V517> + <V518> * <V519>
538
518
539
519
Fig. 6-8: Variable Block 2: Contents of the indexed variables with actual Offset
Factor V518 and actual Index V519
All NC commands using Variables V500-V507 or V510-V517, are
executed in their indexed form.
If access to a variable outside of the range V600 to V999 is made,
(besides system variables), the error message "F- 02 23 – Wrong
variable index" is issued.
If these variables are written via the serial interface, fieldbus or using the
SET command, they are written without an index (directly).