Bosch Rexroth OptiFeed-FS EcoDrive 03 FLP04VRS Functional Description page 464

With integrated nc control
Table of Contents

Advertisement

15-22
EMD Module (EcoX-Bus)
LED
Color
Status
H2
-
off
H2
H3
-
off
H3
green
on
H3
red
blinking
H4
-
off
H4
green
on
H4
red
on
H5
green
blinking
H5
red
on
Definition
correct power supply for the input/output
module
Undervoltage in the input/output module
input/output module is configured as Module 1
(I/O 0...15)
input/output module is configured as Module 2
(I/O 16...32)
watchdog, error executing firmware
firmware test in process
firmware tested and o.k.
firmware tested and contains errors, or
firmware update in process
normal operation
overtemperature
Fig. 15-22: Definitions of General Status Displays and Error-Clearing
Status Displays for the Inputs:
The status displays for the inputs are ready for operation as soon as
supply voltage is applied to the input/output module.
The following table shows the relationship between input voltage, input
value and LED status.
Input Voltage
DC –3 V - 5 V
DC 5 V - 11 V
DC 11 V - 30 V
Fig. 15-23: Switching Threshold of the Inputs
Status Displays for the Outputs
If an output is set to "1," the LED assigned to that output is on.
If an output is set to "1" and the LED is not on, check the following:
• Is the power supply to the outputs connected?
• Is there a short-circuit at the output?
• Is the output turned off in the input/output module because of
overtemperature?
ECODRIVE03-FL*-04VRS
Error-Clearing
Check of the 24V power supply
Turn power supply off and on If the error
occurs again, contact Customer Service.
Wait for firmware update to be executed.
If the error is still occurring, switch from
Phase 2 to Phase 3 again.
Check load on input/output module.
Check ambient temperature, ventilation
and installation.
Input Value
"0"
not defined
"1"
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
LED Status
OFF
not defined
ON