ECODRIVE03-FL*-04VRS
Description:
Clearing the Error:
Description:
Clearing the Error:
Description:
Clearing the Error:
Additional Problems when Loading Firmware
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
0x96FF (dL / 09) Error during write access to RAM
An error occurred during programming. Write access to a memory cell in
the RAM was unsuccessful.
Check whether the target address is actually in the RAM. If the error
continues to appear, it can only be cleared by replacing the ESF02.1
firmware module.
0x9701 (dL / 0d) Wrong checksum
The programmed checksum is validated once the firmware module has
finished updating. This validation check went wrong.
Reprogram the module; validate the checksum of the source file (*.ibf).
0x9702 (dL / 0e) Wrong CRC32 checksum
The programmed CRC32 checksum is validated once the firmware
module has finished updating. This validation check went wrong.
Reprogram the module; validate the checksum of the source file (*.ibf).
The programming of a module was terminated
Problems on the serial interface can lead to the termination of a
transmission.
If the loading procedure for the FBC module was terminated, the unit
must not be switched off. This module is responsible for starting the
firmware and is therefore absolutely necessary.
A module that has not been completely programmed can simply be
reprogrammed (open *.ibf file, press transmit key, select Modules, single
in the "Send" window, and then press the "Skip" key to find the right
module. After that, press the send key).
After switching the unit on, the display reads dL
The last programming procedure with DOLFI was not completed
correctly.
To exit the firmware loader, one or all of the modules of an *.ibf file must
be programmed with DOLFI. The drive firmware is then started by
pressing the "Abort" key.
General Instructions for Start-Up
4-17
Need help?
Do you have a question about the Rexroth OptiFeed-FS EcoDrive 03 FLP04VRS and is the answer not in the manual?