Cam - Bosch Rexroth OptiFeed-FS EcoDrive 03 FLP04VRS Functional Description

With integrated nc control
Table of Contents

Advertisement

ECODRIVE03-FL*-04VRS
? 5 P 0 0 0 6 _ $ h h C R L F
? 5 P 0 1 0 1 _ $ h h C R L F

Cam

Read out Table Values
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
Examples: Readout
Query
Examples: Transmission
# 5 P 0 1 0 3 _ S E T _ _ _ M 2 . 0 2 . 3 _ $ h h C R L F
# 5 P 0 6 0 0 _ R E S C N _ M 2 . 0 2 . 5 _ $ h h C R L F
If no checksum validation function has been programmed prior to entering
Parameter Mode, this function remains disabled, even though Parameter
B002 has been overwritten, until Parameter Mode is exited.
The cam data for the user-programmable cam are stored in the
programming module.
Using the "FLPCAM" program, a CSV file can be transferred to the
control. The number of points on the cam may not exceed 1024. If the
number of points is smaller, the cam is automatically expanded to contain
1024
points.
"MotionManager" CD and must be installed on a PC.
Table Values can be read out in any operating mode.
Format:
? s T n n _ e e e e $ h h C R L F
In response to this request, the control returns the information saved in
the table index.
T s n n _ e e e e _ p p p p p p p p $ h h C R L F
Meaning of the characters used:
s = Station Number
n = Table Number (00 only)
e = Table Element No. (from 0000 to 1023)
p = Standardized Positions [Hexadecimal Value]
(standardized to 2^31)
Note:
An
'????????'.
Response
P 5 0 0 0 6 _ O R N ( _ _ M 2 . 0 2 . 0 _ $ h h C R L F
P 5 0 1 0 1 _ A N D _ _ _ M 2 . 0 2 . 1 _ $ h h C R L F
The
FLPCAM
program
invalid
position
(>$7FFFFFFF)
10-31
Interface
can
be
found
on
returns
the
value
the