Return Water Flow Control - ABB DressPack IRB6650S Product Manual

Table of Contents

Advertisement

2.6.2 Return water flow control

Overview
The mechanical flow control valve is pre-set at delivery at 8 liter/min (maximum
flow).
Settings
The procedure below details how to set the mechanical flow control valve.
1
2
3
Product manual - DressPack/SpotPack IRB 6650S
3HAC055424-001 Revision: C
Action
Open the solenoid valve on the water inlet.
Water flow is indicated on the scale of the Flow
control valve.
Adjust water flow by using the red adjusting knob
on the scale of the Flow control valve to the required
set flow.
© Copyright 2004-2018 ABB. All rights reserved.
2 Installation
2.6.2 Return water flow control
Note
The red adjusting knob is placed
on the back of the Water and Air
unit.
199

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Spotpack irb6650s

Table of Contents