Remove the front part of the protection hose
1
2
3
4
5
Product manual - DressPack/SpotPack IRB 6650S
3HAC055424-001 Revision: C
4.2.15 Replacing the protection hose - IRBDP SW6 UI and MH6 UI
Action
Remove the hose clamp securing the cable and
hose retainer.
Remove the cable and hose retainer.
Remove the hose clamps (2 pcs) securing the
hose reinforcement funnel.
Remove the hose reinforcement funnel (two
parts).
Carefully pull the cables and hoses out and re-
move the front part of the protection hose.
Tip
The following order is preferred:
1 Cables with small connectors
2 Hoses
3 Cables with large connectors
© Copyright 2004-2018 ABB. All rights reserved.
4 Repair
Continued
Note
xx1200000159
xx1200000103
xx1400000209
xx1400000210
Continues on next page