ABB DressPack IRB6650S Product Manual page 84

Table of Contents

Advertisement

2 Installation
2.2.6.2 Fitting the cable packages IRBDP MH2 LE and IRBDP SW2 LE
Continued
6
7
8
Continues on next page
84
Action
Replace the blank cover plates (covering the
holes for customer and process plates), with
the customer plate and process plate.
Use existing screws.
Shown in the figure above.
Fit the adapter complete to the customer
plate with the two attachment screws.
Run the cables down through the center hole
of the gearbox axis 1, in the following order:
Signal cables
Hoses, slightly to the right of the sig-
nal cables
Check that the signal cables and
hoses do not end up between the
motor cables
Check that cables and hoses do not
cross each other.
© Copyright 2004-2018 ABB. All rights reserved.
Note
Note
Removal of blank cover plates only
needed if the DressPack cable package
is fitted for the first time.
xx0300000195
Parts:
A: Adapter complete
B: Attachment screws M6x16
quality 8.8-A2F (2 pcs)
Product manual - DressPack/SpotPack IRB 6650S