4 Repair
4.2.3 Replacing the cable packages IRBDP MH2 LE and SW2 LE
Continued
6
7
8
9
10
Continues on next page
242
Action
Disconnect all hoses from the customer and
process plates.
Note
It is very important to disconnect the hoses
to drain them from water before the discon-
nection of the cable connectors. This will
minimize the risk of getting water into the
electrical connectors.
Disconnect the cable connectors from the
customer and process plates.
Loosen the weld cable clamp and pull the
weld cable through the center hole of gear-
box axis 1.
Loosen the cable and hose clamp.
Pull the lower end of cable package out
through the hole in gear box axis 1.
Order of disassembly:
1 Hoses
2 Signal cables
© Copyright 2004-2018 ABB. All rights reserved.
Note
xx0500001421
Parts:
A: Cable and hose clamp
B: Attachment screw (2 pcs)
Product manual - DressPack/SpotPack IRB 6650S
3HAC055424-001 Revision: C
B
A