2 Installation
2.6.1 Installation of Water and air unit
Continued
Hoses connecting Robot and Water and Air unit
Use this procedure to connect hoses between robot and Water and Air unit.
1
2
3
4
5
6
198
Action
CAUTION
Do not tighten the brass couplings for water
and air with excessive force.
Connect Proc 1 on the Water and Air unit
with Proc 1 on the robot.
Connect Proc 2 on the Water and Air unit
with Proc 2 on the robot.
Connect Proc 3 on the Water and Air unit
with Proc 3 on the robot.
Connect Proc 4 on the Water and Air unit
with Proc 4 on the robot.
Secure all connectors.
© Copyright 2004-2018 ABB. All rights reserved.
Note
Tightening torque, brass couplings 1/2":
31Nm
Tightening torque, brass couplings 3/8":
17Nm
If second water return or regulated air is
used.
See Tightening torques in section
joints on page
351.