2 Installation
2.2.6.2 Fitting the cable packages IRBDP MH2 LE and IRBDP SW2 LE
Continued
12
13
14
Continues on next page
86
Action
Fit the connectors to the customer and pro-
cess plates, previously fitted to the connec-
tion plate base.
CAUTION
Do not tighten the brass couplings for water
and air with excessive force.
Tip
In order to get the weld power cable moun-
ted in the right position on the process plate,
first connect the floor weld cable to the weld
power cable and use it as a guide.
Before tightening the weld power attachment
screws, make sure that the cable connector
is evenly placed in the hole of the process
plate.
Tighten the weld power cable attachment
screws.
Secure the cable package to the gripping
clamp on the frame.
© Copyright 2004-2018 ABB. All rights reserved.
Note
Shown in the figure in section
of lower arm cable package on page
Tightening torque, brass couplings 1/2":
31Nm
Tightening torque, brass couplings 3/8":
17Nm
Recheck all cables and hoses for strain-
ing or twisting. Reroute if required!
Screw dimension: M6x20 quality 8.8.A2F
(4 pcs to each plate).
The attachment screws of the weld power
cable are shown in the figure above.
A
xx0500001425
Parts:
A: Gripping clamp
Product manual - DressPack/SpotPack IRB 6650S
3HAC055424-001 Revision: C
Location
80.