GLASS
23-35
frame and lower run channel. The index notch at the
door upper corner should be positioned first to as-
sure correct installation of the run. The lower run
channel (Fig. 72) is positioned over the window open-
ing frame from inside the door through the large
access opening.
Vent Wing
IAR
Models)
Removal
(1) Remove the arm rest, inside
control lock knob, panel and water
(2) Disengage the lower end of
from the adjusting bracket (Fig.
64).
handles, remote
shield.
the division bar
(3) Remove the two attaching screws from the for-
ward and top edge of the door frame.
(4)
Remove the two vent frame attaching screws
from the base of the vent frame.
(5) With the door glass in the down position,
tilt
the vent frame to the rear and withdraw the vent
frame assembly up out of the door.
Installation
(1)
With the door glass in the down position, tilt
the vent frame assembly to the rear and insert the
division bar and vent assembly into the door.
(2) Install the two lower vent frame attaching
screws finger tight.
(3) Install the two vent frame attaching screws in
the forward and top edge of the door frame.
(4)
Tighten the vent frame lower attaching screws.
(5) With the door glass in the down position attach
the lower end of the division bar to the adjusting
bracket.
(6)
Operate the door glass and inspect for ease of
operation and alignment of the division bar.
(7) Install the door water shield, trim panel and
hardware.
Vent Wing
(AV Models)
Removal
(1)
Remove the interior trim and hardware from
the door.
(2) Remove the lock nut and washer from the low-
e r vent frame stud (Fig.
65).
(3) Remove the attaching screws from the vent
frame.
(4)
With tho door glass in the down position, dis-
engage the lower frame stud from the door bracket,
the window regulator arms from the window channel
and slide the window out of the run channels.
(5) Disconnect the cat whisker for a short distance
to provide clearance for the vent wing division chan-
nel.
(6)
Pull the stop of the vent frame toward the rear
of the door and slide the assembly up out of the door.
lnstallution
Before installing the vent glass assembly, lubricate
and test the tension of the vent wing lower pivot.
(1) Place the vent assembly into door.
(2) Move the vent frame forward into position.
(3) Install the attaching screws.
Do not
tighten.
(4)
Reinstall the door glass in the run channel and
( 5 ) Position the lower run channel adjusting stud
(6)
Align the window run channel.
(7)
Install the door trim, hardware and cat whisker.
install the regulator arms and clips.
into the door bracket.
Door
Glass
Removal
IAR
Models)
(1)
Remove the inside door handles, arm rest, re-
mote lock knob, trim panel and water shield.
(2) With the glass in the down position, insert a
screwdriver under the retainer ring and pry the re-
tainer from both regulator arm studs (Fig. 73).
(3) Remove the leather washers from the regulator
arm stud, then pull the regulator arm studs from the
glass lower channel.
(4)
Loosen the division bar and front run channel
mounting bolt.
(5) Move the division bar forward and disengage
from the door glass.
(6)
Move the glass forward between the division
bar and the inner door panel and remove the glass
up through the door frame.
Installation
(1) Insert the door glass down into the door frame.
(2) Lubricate the slides of the glass lower channel
(3) Insert the glass into both front and rear run
(4)
Insert the regulator studs into the slides of the
(5) Install the leather washers and new retaining
with lubriplate.
channels.
glass lower channel.
clips on the ends of the studs.
RETAINER
64
x
433
Fig. 73-Regulator
Stud Retainer