HEADLAMPS
8-65
NOTE: Make sure that the line of sight is perpen-
dicular from the eye to the viewing port of the
transit and that the target image is centered in
viewing port of transit.
(3) Turn the dial on the side of the transit until
the bubble in the spirit level is centered.
(4)
When the bubble
is
centered, note "plus" or
"minus" reading on the compensator scale. This figure
indicates the degree of slope of the floor and must be
transferred to each aimer.
(5)
With a screw driver, turn the adjusting slot of
the floor level compensator in each aimer, until the
correct plus or minus figure (or fractional part) ap-
pears in the proper window, Fig,
2.
Testing Aimer Calibration Wig.
31
(1) Using a carpenter or stone mason level of
known accuracy, locate a true vertical plate glass win-
dow or smooth surface.
(2)
Set the
DOWN-UP
pointer on
DOWN
2.
(3)
Set the
RIGHT-LEFT
pointer and the floor level
compensator at "0."
(4)
Secure the aimers to the glass or smooth sur-
face three to five feet apart so split image targets can
be located in the viewing ports.
(5)
If the bubble is centered in the glass dial, ver-
tical calibration is correct. If the bubble is not cen-
tered, make the
DOWN-UP
adjustment by rotating
the level adjusting screw until the bubble is centered
in the spirit level.
(6)
The horizontal aim is correct
if
the targets on
opposite aimers are aligned in the viewing ports. I f
the targets are not aligned in the viewing ports, ro-
tate the mirror adjusting screw until the target split
image becomes aligned.
MOUNTING AND ADJUSTING THE AIMERS
(1)
While holding an aimer in alignment with the
Fig. 3--Testing
Aimer for Calibration
Fig. L M o u n t i n g and Adjusting Aimers-
Model AP-1 and AP-2 Arrangement Shown
lens of one headlamp on Models AV-1, AV-2, AR-1
and AR-2 and on an upper (top) headlamp on Models
AP-1 and AP-2, bring the aimer up to and against the
headlamp lens.
NOTE: Make certain that the headlamp lens pads
are making full contact with the aimer mounting
flange and that the aimer target is facing inboard.
(2)
Push the release lever forward (to expel air from
suction cup) and while holding the aimer firmly
against the headlamp aiming pads, slowly pull the
release lever back until the spring lock engages in
the slot, Fig.
4.
(3)
Mount the second aimer on the other side of
the vehicle, in the same manner.
(4)
On each aimer, set the pointer to numeral
2
the
DOWN
side of the
DOWN-UP
scale.
(5)
On each aimer position the pointer, of the
RIGHT-LEFT
scale, at
2-RIGHT.
MEASURING
HEADLAMP
AIM
Horizontal
Test
Turn the RIGHT-LEFT scale knob until the split
image is in alignment. If the
RIGHT
or
LEFT
POR-
TION of scale exceeds the following values, the lamps
should be aimed.
Values given represent inches at
25
feet.
Right
Lefi
No. 1 Unit
. . . . . . . . . . . . . . . . . .
4
4
No. 2 Unit
4
4
Vertical
Test
Turn
DOWN-UP
scale knob until the spirit level is
centered. If
Down
or
Up
portion of the scale exceeds
the following values, the lamps should be aimed.
. . . . . . . . . . . . . . . . . .
Down
UP
No.
1 Unit
. . . . . . . . . . . . . . . . . .
% to
3%
0
No.
2
Unit
. . . . . . . . . . . . . . . . . .
% to 3%
0

Hide quick links: