a-a0
SIX WAY POWER SEATS
LEFT SEAT
TRACK ASSEMBLY,
FLEXIBLE CABLES AND
TUBES /ASSEMBLY
Fig. 2-Removing
Cables from Drive Assembly
assembly to the left guide bracket.
left slave unit (Fig.
4).
(7)
Remove the drive assembly with tubes from the
(8)
Remove the flexible cables from the tubes.
Installation
CAUTION:
Seat guides should
be in the up and for-
ward position when installing cables. Make sure
both guides are at the same position (in alignment).
(1)
Place the three left cable tubes into the left
slave unit (Fig. 5).
(2)
With the shortest tube on the inside and long-
est on
the outside, install the flexible cables in the
tubes. Make sure the cables seat in the slave unit.
(3) Position the drive unit on the left side tubes.
Make sure the flexible cables seat in the slot in the
drive unit.
~
RIGHT SEAT
TRACK ASSEMBLY
CABLE MOUNTING BRACKET
BRACKET MOUNTING
SCREWS
FLEXIBLE CABLES AND
TUBES ASSEMBLY
63x633
Fig. 3-Removing
Cables from Right Slave Unit
DRIVE ASSEMBLY
63x630A
Fig. 4-Removing
Drive Assembly from
Left Slave Unit
(4)
Bolt the drive unit to the guide bracket.
(5) Place the right side flexible cables in the right
side tubes.
(6) Position the left guide and drive assembly
on
the right side tubes. Make sure
the
cables seat in the
drive assembly.
(7)
Install the right side tubes retainer plate.
(8) Bolt the left guide assembly to the floor.
(9)
Install the seat and cushion assembly.
(10) Connect
the red feed wire and test the opera-
tion of the seat.
SEAT MOTOR (Fig. 6)
Removal
(1) Remove the two mounting stud attaching
nuts
-RIVE
CABLES
KRl 89
Fig. 5 - / n s t a l l i n g Left Cable Tubes
in
Slave Unit