Download Print this page

Plymouth Valiant V-100 1965 Service – Technical Manual page 170

Advertisement

8-26
ALTERNATOR AND REGULATOR
SPACER
RETAINER--
SH PACKAGE
62 x 2A0A
BEARING
Fig. 3-Alternotor
fbirorrembled V k w l
VOLTAGE REGULATOR
The only function of the regulator
is
to limit the
output voltage. The voltage regulator accomplishes
this by controlling the flow
of current in the rotor
'field coil, and in effect controls the strength of the
rotor magnetic field.
The voltage regulator is connected in the field cir-
cuit between the battery and the field terminal of the
alternator. One terminal of the regulator
is
marked
"IGN" and the other is marked "FLD." The "IGN'
terminal of the regulator is connected to the coil side
of the ignition switch
so that the
field circuit is com-
pleted
only
when the ignition switch is turned "ON."
The voltage regulator (Fig.
4)
has two sets of con-
tacts using a common single armature. The upper and
lower stationary contact brackets are mounted on a
molded plastic bracket which is attached to the regu-
lator frame by a screw. (Fig.
5)
The upper contact
bracket
is
connected to the "IGN" terminal
bv
a fusi-
Three resistance units are used (Fig.
6).
Resistor
number "one" and number "two"
are
connected be-
tween the "IGN" and "FLD" terminals, in parallel
with the upper
set of
contacts. Resistor number
"three"
is
connected between the "FLD" terminal
and ground. Its function is to reduce arcing at the
=
-
OI
ble
wire. The lower contact bracket is connected to
ground by another fusible wire. The armature
is
con-
nected to the insulated "FLD" terminal.