CHAPTER 14 16-BIT RELOAD TIMER
[bit1] CNTE (Timer counter enable)
This bit enables the timer counter.
CNTE
0
1
[bit0] TRG (Software trigger)
This bit operates as a software trigger bit. With TRG set to "1", a software trigger is applied,
data from the timer reload register is loaded into the counter and counting starts. Writing "0"
has no effect. Read operations always read "0". Only when CNTE = 1, this bit is valid
irrespective of the operation mode.
TRG
0
1
300
Counter operation stopped (initial value)
Counter operation allowed (start trigger wait)
No change (initial value)
Count operation start
Function
Function