History-Command Max-Size - 3Com 7750 Series Command Reference Manual

3com switch command reference guide
Hide thumbs Also See for 7750 Series:
Table of Contents

Advertisement

3Com Switch 7750 Series
Command Reference Guide – Login
(The beginning and end characters of the banner are not displayed.)
<3Com>
Option 2: Enter the banner in multiple lines.
<3Com> system-view
System View: return to User View with Ctrl+Z.
[3Com] header shell %SHELL:
(Following appears after you press <Enter>:)
Input banner text, and quit with the character '%'.
Continue entering the banner and end the banner with the character identical with the
beginning character of the banner.
Hello! Welcome %
(Press <Enter>.)
[3Com]
When you log in the next time, the session banner appears on the terminal as the
following:
[3Com] quit
<3Com> quit
Please press ENTER
%SHELL:
(Note that the beginning character of the banner appears.)
Hello! Welcome
<3Com>

1.1.9 history-command max-size

Syntax
history-command max-size value
undo history-command max-size
View
User interface view
Parameter
value: Size of the history command buffer. This argument ranges from 0 to 256 and
defaults to 10. That is, the history command buffer can store 10 commands by default.
Description
Use the history-command max-size command to set the size of the history
command buffer.