Syslogserver - Siemens SCALANCE XM-400 Configuration Manual

Simatic net industrial ethernet switches command line interface
Hide thumbs Also See for SCALANCE XM-400:
Table of Contents

Advertisement

The parameters have the following meaning:
Parameters
up
down
ifXtype
iface_list
For information on names of addresses and interfaces, refer to the section "Addresses and
interface names (Page 30)".
If you do not select an interface, the function is disabled for all available interfaces.
Result
The settings for monitoring the physical network connections have been configured.
Further notes
You can display the current setting with the
You enable the function with the
12.1.14.14

syslogserver

Description
With this command, you configure the Syslog server address.
Requirement
You are in the EVENTS configuration mode.
The command prompt is as follows:
cli (config-events) #
Syntax
Call up the command with the following parameters:
syslogserver {ipv4 <ip address> | fqdn-name <FQDN(100)>} [<port(1-65535)>]
SCALANCE XM-400/XR-500 Command Line Interface
Configuration Manual, 05/2014, C79000-G8976-C252-07
Description
The message when establishing a connection is
disabled
The message when a connection is down is
disabled
Type or speed of the interface
Slot no. and port no. of the interface
command.
link
12.1 Event and fault handling
Range of values
-
-
Enter a valid interface name
show events faults config
Diagnostics
gigabitethernet
extreme-ethernet
command.
565

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scalance xr-500

Table of Contents