Mitsubishi Electric GT16 User Manual page 1299

Got1000 series
Hide thumbs Also See for GT16:
Table of Contents

Advertisement

REVISIONS
Print Date
* Manual Number
Jul., 2010
JY997D41201
JY997D41202
Jan., 2011
JY997D41201
JY997D41202
Apr., 2011
JY997D41201
JY997D41202
Jul., 2011
JY997D41201
JY997D41202
Oct., 2011
JY997D41201
JY997D41202
Jan., 2012
JY997D41201
JY997D41202
Apr., 2012
JY997D41201
JY997D41202
Sub
Number
A
First edition
B
Compatible with GT Designer3 Version1.23Z
• Error code list added, Error message of duplicate IP address added
• CF card with 4GB, 8GB, and 16GB supported
• The [OK] button is changed to the [OK]/[Cancel] buttons
• Compatible with "no setting" of the utility call key
• Compatible with the setting of [Operating priority guaranteed time]/[Operation status popup
notification] in the [SoftGOT-GOT link] screen
• Compatible with the display of GOT information
• Compatible with the Ethernet settings check and the change of the host
• Compatible with the setting of [Comment setting] in the [Q/L/QnA ladder monitor] screen
• Compatible with the Ethernet connection status check with the ping transmission
• Compatible with the display of GOT start time history in Batch self check
• Compatible with the latest display in Operation log information
• Compatible with CC-Link IE Field Network Ethernet adapter module
• Station monitoring function (Inverter connection) compatible
• Inverter connection with 31 modules, device range expansion compatible
• FA transparent in GOT multi-drop connection compatible
• FA transparent MR Configurator2 compatible
• FA transparent in LCPU Logging Configuration Tool compatible
• FA transparent in Ethernet connection between GOT and personal computer compatible
• IAI Corporation robot controller (PCON, ACON, SCON) compatible
• OMRON PLC (CJ2M) compatible
• CHINO controller (KP, AL3000, AH3000, SE3000, JU, KE, LE5000) compatible
• TOSHIBA PLC (Unified Controller nv Series) compatible
• YAMATAKE temperature controller (DMC50) compatible
• RKC temperature controller (RB500, RB700, PF, HA, RMC, MA, AG, THV) compatible
• Microcomputer connection (Ethernet) formats 8 and 9 (QnA compatible 3E frame) compatible
C
Compatible with GT Designer3 Version1.28E
• Compatible with the specification change of the numeric keyboard
• KEYENCE (KV-5500) compatible
• YASKAWA PLC (CP-317) compatible
• RKC temperature controller (Z-CT, SRX, SA) compatible
• Ethernet connection with SIEMENS PLC (SIMATIC S7-300/400 series) compatible
D
Compatible with GT Works3 Version1.31H
• Compatible with the save setting of multiple ladder data of Q/L/QnA ladder monitor
• Compatible with the communication setting storage and error information notification in GOT
multi-drop connection
• Compatible with the connection with PANASONIC servo amplifier (MINAS A5 series)
• Compatible with the connection with YOKOGAWA temperature controller (UTAdvanced)
E
Compatible with GT Works3 Version1.37P
• IAI Corporation robot controller (ASEL, PSEL, ERC2) compatible
• Motion program (SV43) I/O compatible
F
Compatible with GT Works3 Version1.40S
• "I/F Communication Setting" is compatible with "5V power supply"
• VNC
server function supported
G
Compatible with GT Works3 Version1.45X
• The backup/restoration setting function is added
• FX
compatible
3GC
• Q172DSCPU/Q173DSCPU compatible
• The supplemental explanation for Ethernet cascade connection is added and the writing errors are
corrected
• HITACHI IES PLC (EH-CPU516, EH-CPU548) compatible
• YASKAWA PLC (MP2300S) compatible
* The manual number is given on the bottom left of the back cover.