Error code list
In the case of format 2 (GOT-A900 series microcomputer connection (format 2)), the error contents (error code) are
appended to the response message during faulty communication.
The following shows error code, error contents, cause, and measures.
Error code
Sum check error
06
The sum check code created from received data differs
H
from the sum check code in the receive data.
Command error
10
H
An unsupported command was used.
Message length error
11
The upper limit of the data length that can be received by
H
the GOT has been exceeded.
Communication message error
12
EXT was not found within the upper limit of the receive
H
buffer.
Clock data setting error
15
H
The setting value of the clock data has error.
Address error
7A
H
The start address of the read/write device is out of range.
Exceeded number of points error
7B
H
The read/write range exceeded the device range.
Precautions
(1) Batch reading/writing crossing over different devices
When using the batch read (RD) or batch write (WD) command, do not batch read/write crossing over the
different devices.
This will cause an error response.
(2) Storage order for 32-bit data
To use the program of GOT-A900 series with [32bit Order] setting to GOT1000 series, set [HL Order] to [32bit
Order] for [Communication Detail Settings] when 32-bit data is set for GOT-A900 series.
With setting [LH Order], the order of upper bits and lower bits are reversed when the GOT displays and writes
32-bit data.
Description
61. MICROCOMPUTER CONNECTION (SERIAL)
Measures
• Review the contents of the message to transmit.
• Review the contents of the message to transmit.
• Check the commands in the message.
(
61.5.2 List of commands)
• Review the contents of the message to transmit.
• Check the data length of the message. (data length of the data section,
etc.)
• Check the communication cable and communication module attachment.
• Check the settings of "Communication Detail Settings".
• Review the contents of the message to transmit.
• Review the contents of the message to transmit.
• Check whether the non-existent data is set (e.g. setting "07" at the day of
the week) as clock data.
• Review the contents of the message to transmit.
• Check the devices that can be used and the device ranges.
(
61.4 Device Data Area)
61.5 Message Formats
60
61
62
63
64
65
61 - 31