Formats 14, 15 (Got-F900 Series Microcomputer Connection) - Mitsubishi Electric GT16 User Manual

Got1000 series
Hide thumbs Also See for GT16:
Table of Contents

Advertisement

61.5.7 Formats 14, 15 (GOT-F900 Series microcomputer connection)

Basic format of data communication
Item
(format 14: GOT-F900 Series microcomputer connection (format
1))
(1) w/out station No.
Request message
(host
GOT)
(2) w/station No.
(1) During processing of read commands
(format 14: GOT-F900 Series microcomputer connection (format 1))
Response message
during normal
communication
(GOT
host)
(2) During processing of write commands
Response message
during faulty
communication
(GOT
host)
During interrupt
output
*1
Set the number of interrupt data bytes at [Detail Setting] in GT Designer3.
For the setting of the number of interrupt data bytes, refer to the following.
61 - 52
61. MICROCOMPUTER CONNECTION (SERIAL)
61.5 Message Formats
Com-
STX
Data
CR
mand
02
H
Com-
STX
Station No.
Data
mand
02
H
(H)
(L)
Data
STX
02
H
61.6.1 Setting communication interface (Communication settings)
Message format
(format 15: GOT-F900 Series microcomputer connection (format
2))
(1) w/out station No.
0D
H
(2) w/station No.
CR
STX
0D
02
H
(format 15: GOT-F900 Series microcomputer connection (format 2))
STX
CR
02
0D
H
H
ACK
06
H
NAK
15
H
Output
value
1/2/4
bytes
*1
Com-
STX
Data
ETX
mand
02
03
H
H
Sum check is performed in this range.
Com-
Station No.
Data
mand
H
(H)
(L)
Sum check is performed in this range.
Data
Sum check is performed in this range.
Sum
Check
(H)
(L)
Sum
ETX
Check
03
H
(H)
(L)
Sum
ETX
Check
03
H
(H)
(L)

Advertisement

Table of Contents
loading

Table of Contents