LIGHTS/METER/SWITCHES
POWER/GROUND LINE INSPECTION
If any indication in the combination meter is abnor
mal, check the following item.
Remove the meter cover (page 2-5).
Remove the dust cover.
Check the following at the wire harness side con
nector terminals of the combination meter.
Power input line
Measure the voltage between lhe Black/brown wire
terminal (+) and body ground (-).
There should be battery voltage with the ignition
switch ON.
If there is no voltage, check for open circuit in Black/
brown wire.
Back-up voltage line
Measure the voltage between the Red/green wire
terminal (+) and body ground(-).
There should be battery voltage at all times.
If there is no voltage, check for open circuit in Red/
green wire.
Ground line
Measure the continuity between the Green/black ,--------------------
wire terminal and body ground.
There should be continuity.
If there is no continuity. check for open circuit in
Green/black wire.
20-12
,----------- -------- -
Viewed from harness side/
the 20P connector:
Viewed from harness side/
the 20P connector:
Viewed from harness side/
the 20P connector: