Honda CB 600F Hornet 2007 Shop Manual page 485

Table of Contents

Advertisement

ANTI-LOCK BRAKE SYSTEM (ABS; CB600FA)
3. Relay Power Input Line Open Circuit Inspection
(at control unit side)
Install the "ABS FAIL-SAFE RELAY" fuse.
Disconnect the ABS modulator 25P connector.
Measure the voltage between Black wire termi­
nal (+) of the 25P connector and ground (-).
There should be battery voltage at all times.
TOOL:
Test probe
CONNECTION: Black(+) - Ground (-)
Is there battery voltage?
YES
NO
4. Relay Power Input Line Open Circuit Inspection
(at fuse box side)
Disconnect the sub fuse box 4P connector.
Measure the voltage between Black wire termi­
nal (+) of the fuse box side 4P connector and
ground (-). There should be battery voltage at all
times.
CONNECTION: Black (+I
Is there battery voltage?
YES
NO
5. Failure Reproduction
Connect the ABS modulator 25P connector.
Erase the problem code (page 16-9).
Perform the pre-start self-diagnosis (page 16-7).
Retrieve the problem code (page 16-8).
Does the indicator indicate the code "54"?
YES
NO
16-18
07ZAJ-RDJA 110
- GO TO STEP 5.
- GO TO STEP 4.
-
Ground
- Open circuit in Black wire between the
fuse box and control unit.
- Open circuit in Black wire between the
battery and fuse box 4P connector.
- Faulty ABS modulator.
- Normal (problem code is not stored;
temporary failure).
MODULATOR 25P CONNECTOR
(Wire side/female terminals)
SUB FUSE BOX 4P CONNECTOR
(Fuse box side/female terminals)
(-)
ABS INDICATOR
• '
.
QIHlllaa
@
\�
Black
'
'�
'
'�
��
::'.
.,.,..n,,
\
I
@)

Hide quick links: