Honda CB 600F Hornet 2007 Shop Manual page 527

Table of Contents

Advertisement

Install the starter motor into the crankcase.
Install the ground cable and mounting bolts, and
Roura rho w,ros
1- tighten the bolts securely.
properly (page
Install the starter motor cable, then tighten the ter­
23 )
minal nut to the specified torque.
TORQUE: 10 N•m (1.0 kgf-m, 7 lbf•ft)
Install the rubber cap securely.
Install a new O-ring into the groove of the water
hose joint.
Install the water hose joint to the cylinder block.
Tighten the bolts securely.
Install the following:
-
thermostat (page 6-10)
-
air cleaner housing (page 5-75)
Connect the battery negative cable.
STARTER RELAY SWITCH
OPERATION INSPECTION
Remove the seat (page 2-4).
Shift the transmission into neutral.
Turn the ignition switch ON and engine stop switch
" O" .
Press the starter switch button.
The coil is normal if the starter relay switch clicks.
If you don't hear the switch "click", inspect the relay
switch using the procedure below.
GROUND LINE INSPECTION
Disconnect the starter relay switch 4P connector.
Check for continuity between the Green/red wire
(ground line) and ground.
If there is continuity when the transmission is in
neutral and clutch lever released or when the clutch
lever pulled and the side stand up, the ground cir­
cuit is normal (In neutral, there is a slight resistance
due to the diode).
ELECTRIC ST ARTER
19-15