Honda CB 600F Hornet 2007 Shop Manual page 490

Table of Contents

Advertisement

5. Indicator Operation Inspection
Remove the meter cover (page 2-5).
Remove the dust cover.
With the connector connected, short the Red/
black wire terminal of the combination meter
20P connector and ground with a jumper wire.
Check the ABS indicator with the ignition switch
turned to "ON".
Does it go off?
YES
- GO TO STEP 6.
NO
- Faulty combination meter.
6. Indicator Signal Line Open Circuit Inspection
Remove the jumper wire from the combination
meter 20P connector.
Short the Red/black wire terminal of the 25P con­
nector and ground with a jumper wire.
Check the ABS indicator with the ignition switch
turned to "ON'".
Does it go off?
YES
- GO TO STEP 7.
NO
- Open circuit in Red/black wire between
the combination meter and ABS modu­
lator.
7. Logic Ground Line Open Circuit Inspection
Remove a jumper wire from the ABS modulator
25P connector.
Short the Red/black and Green/orange #1 wire
terminals of the 25P connector with a jumper
wire.
Check the ABS indicator with the ignition switch
turned to '"ON"'.
Does it go off?
YES
- • Faulty ABS modulator.
NO
- • Open circuit in Green/orange wire
between the ABS modulator and
body ground.
ANTI-LOCK BRAKE SYSTEM (ABS; CB600FA}
MODULATOR 25P CONNECTOR
{Wire side/female terminals)
Red/black
MODULATOR 25P CONNECTOR
{Wire side/female terminals)
Green/orange #1
16-23