Honda CB 600F Hornet 2007 Shop Manual page 484

Table of Contents

Advertisement

5. Failure Reproduction
Connect the ABS modulator 25P connector.
Erase the problem code {page 16-9).
Perform the pre-start self-diagnosis (page 16-7).
Retrieve the problem code {page 16-8).
Does the indicator indicate the code "51, 52, or
53"7
YES
- Faulty ABS modulator.
NO
- Normal {problem code is not stored;
temporary failure).
PROBLEM CODE 54 (Fail-safe Relay)
1. Fuse Inspection
Remove the seat (page 2-4).
Check the "'ABS FAIL-SAFE RELAY"" fuse (30A) in
the ABS fuse box for blown.
Is the fuse blown?
YES
- GO TO STEP 2.
NO
- GO TO STEP 3.
2. Relay Power Input Line Short Circuit Inspection
Disconnect the ABS modulator 25P connector.
Check for continuity between the Black wire ter•
minal of the 25P connector and ground with
"ABS FAIL-SAFE RELAY" fuse removed.
TOOL:
Test probe
CONNECTION: Black - Ground
Is there continuity?
YES
- Short circuit ln Black wire between the
fuse box and ABS modulator.
NO
- Temporary failure (install a spare fuse
and recheck from the first step)
ANTI-LOCK BRAKE SYSTEM (ABS; CB600FA)
MODULATOR 25P CONNECTOR
(Wire side/female terminals)
07ZAJ-RDJA110