VoiceFinder AP200 VoIP Residential Gateway (RGW) User's Guide Version 1.1
5.7.5.13.2.
Default value
In case of G.7231, default value is 1. This means that audio frame is generated
and transmiting RTP packet at every 30ms interval.
Default value is 2 in case of G.729. This means that audio frame is generated at
10ms interval and transmiting RTP packet at 20ms interval.
5.7.5.13.3.
Command Mode
Voice-Service setting mode
5.7.5.13.4.
Usage Guideline
Generally, if bandwidth is low or congestion is occurred in internet, increase the
max-frame length. At first step, increase the max-frame length as 2 in G.7231,
4 in G.729. If this does not work well, increase the max-frame length as 3 in
G.7231, 6~8 in G.729. Buf, if max-frame is too large, this feature have
transmission delay problem. In cable network that have poor upstream network
environment, this command with qos-control command will enhance the voice
quality.
5.7.5.13.5.
Examples
Qos-control and max-frame setting examples for cable modem network.
interface ethernet 0 0
qos-control 128 100
voice service voip
max-frame g729 4
max-frame g7231 2
5.7.5.14.
gkip
To specify the gatekeeper associated with a proxy and control how the
AddPac Technology Co.,Ltd.
268
-
-
Need help?
Do you have a question about the VoiceFinder AP200 and is the answer not in the manual?