VoiceFinder AP200 VoIP Residential Gateway (RGW) User's Guide Version 1.1
5.7.3.11.2.
Default Value
No shutdown
5.7.3.11.3.
Command Mode
Voice-port configuration Mode
5.7.3.11.4.
Usage Guideline
When you enter the shutdown command, all ports on the voice interface card
are disabled. When you enter the no shutdown command, all ports on the
voice interface card are enabled. A telephone connected to an interface will
hear dead silence when a port is shut down.
5.7.3.11.5.
Examples
The following example takes voice port 1/3 on the router offline:
configure
voice-port 1/3
shutdown
5.7.3.12.
translate-incoming
To apply the translation rule to the inbound POTS call coming to the
corresponding voice port, use this command. To stop applying the translation
rule, use "no" command before "translate-incoming" command.
translate-incoming { called-number | calling-number } tag
no translate-incoming { called-number | calling-number }
5.7.3.12.1.