Usage Guideline
Use the ring number command to set the maximum number of rings to be
detected before answering a call over an FXO voice port. Use the no form of
this command to reset the default value, which is one ring.Normally, this
command should be set to the default so that incoming calls are answered
quickly. If you have other equipment available on the line to answer incoming
calls, you might want to set the value higher to give the equipment sufficient
time to respond. In that case, the FXO interface would answer if the equipment
on line did not answer the incoming call in the configured number of rings.This
command is not applicable to FXS or E&M interfaces because they do not
receive ringing to receive a call.
5.7.3.10.5.
Examples
The following example on the router sets five rings as the maximum number of
rings to be detected before closing a connection over this voice port:
voice-port 1/1
ring number 5
5.7.3.11.
shutdown (voice-port)
To take the voice ports for a specific voice interface card offline, use the
shutdown voice-port configuration command. Use the no form of this
command to put the ports back in service.
shutdown
no shutdown
5.7.3.11.1.
Syntax
This command has no arguments or keywords