VoiceFinder AP200 VoIP Residential Gateway (RGW) User's Guide Version 1.1
At this time, the originating subscriber hears the dial tone that the PABX sends
and will enter 100.
To change two-stage dialing into one-stage dialing, users shall set the VoIP
peer of Router A as follows:
dial-peer voice 555 VoIP
destination-pattern 310555.......
In this kind of setup, the subscriber of Router A shall enter 3105551000100 to
establish a call, and Router B sends called party number and other digits than
fixed digit information except the wildcard of the destination pattern to the
voice port when the outbound POTS peer is selected as 1000. In this case 100
is sent.
If the length of the inter-working number is not fixed, it is better to use "T" as the
destination pattern.
Set the VoIP peer of Router A as follows:
dial-peer voice 555 VoIP
destination-pattern 310555T
In this case, if the subscriber of Router A enters the termination digit (#) after
entering 31055510001234567 or if the inter-digit is timed-out, a call will be
connected to Router B and Router B will send 1234567 to the selected voice
port.