Message (Part Code Group 7Nnn); Part Code 7005 - HP XP P9500 Manual

Hp p9000 remote web console messages (av400-96401, october 2011)
Hide thumbs Also See for XP P9500:
Table of Contents

Advertisement

9 Message (part code group 7nnn)

This chapter includes the error messages with the part code 7005 to 71 10.

Part code 7005

Table 62 Error codes (part code 7005)
Part
Error
Code
Number
7005
5013
7005
5099
7005
5625
7005
5626
7005
5655
7005
5821
7005
6012
7005
6023
7005
6502
7005
6503
7005
7310
7005
8000
7005
8001
7005
8100
7005
8500
7005
8501
244 Message (part code group 7nnn)
Error Message
An error occurred during SVP
processing.
An error occurred during SVP
processing.
An internal logic error occurred.
The specified volume cannot be used
because it is write-protected by Data
Retention.
Volumes specified as P-VOL and S-VOL,
or those constituting LUSE are not
consistent in capacity.
This operation has been rejected. The
Data Retention setting does not allow the
specified volume(s) to be specified as
S-VOL(s).
An error occurred during SVP
processing.
The SVP is busy. Please wait for a while,
and then retry the operation.
Processing in progress. Please wait for
a while, and then retry the operation.
The target volume status is being
changed to SMPL.
This error code is not registered.
A time-out error occurred.
A time-out error occurred.
A time-out error occurred.
Sufficient amount of shared memory is
not installed or the program product is
not installed.
The command has been rejected,
because the command specified last time
is being processed.
Recommended Action
If this problem persists, please contact
HP Technical Support.
If this problem persists, please contact
HP Technical Support.
Please contact HP Technical Support.
Release the write-protection by Data
Retention.
Select volumes with the same capacity.
When specifying LUSE volumes as P-VOL
and S-VOL, the capacity of each volume
constituting the LUSE volumes must be
the same.
Change the setting of Data Retention so
that the specified volumes can be used
as S-VOLs.
If this problem persists, please contact
HP Technical Support.
If the same problem persists despite
retrying, please contact HP Technical
Support.
Wait a while, and retry the operation.
Wait a while, and retry the operation.
If this problem persists, please contact
HP Technical Support.
If the problem persists despite retrying,
please contact HP Technical Support.
Retry the operation. If you get the same
message again, reboot the PC. If
necessary, please contact HP Technical
Support.
If the problem persists despite retrying,
please contact HP Technical Support.
Add shared memory or confirm whether
the necessary program product key is
installed.
Wait a while, and retry the operation.
Severity
Level
E
E
W
W
W
W
E
W
W
W
W
W
W
W
W
W

Advertisement

Table of Contents
loading

This manual is also suitable for:

P9000P9500

Table of Contents