HP XP P9500 Manual page 247

Hp p9000 remote web console messages (av400-96401, october 2011)
Hide thumbs Also See for XP P9500:
Table of Contents

Advertisement

Table 62 Error codes (part code 7005) (continued)
Part
Error
Error Message
Code
Number
7005
8541
There is sufficient shared memory to
create 4096 pairs, and the initial
subsystem setup is complete.
7005
8542
Failed to complete the initial shared
memory setup.
7005
8543
The shared memory size is different.
7005
8544
16 Mbytes of shared memory is
available.
7005
8545
A power supply failure is detected.
7005
8546
The command was rejected. The PS OFF
is in progress.
7005
8547
A data transfer failure is detected (CHA).
7005
8548
A data transfer failure is detected (DKA).
7005
8549
The P-VOL is not implemented.
7005
8550
The command has been rejected,
because the specified P-VOL is blocked
or used as a system disk.
7005
8551
The P-VOL is being formatted.
7005
8552
This volume cannot be specified as an
P-VOL because it is used as a command
device.
7005
8553
The S-VOL is not implemented.
7005
8554
The command has been rejected,
because the specified S-VOL is blocked
or used as a system disk.
7005
8555
The S-VOL is being formatted.
7005
8556
This volume cannot be specified as an
S-VOL because it is used as a command
device.
7005
8557
The volume is not implemented.
7005
8558
The command has been rejected,
because the specified volume is blocked
or used as a system disk.
7005
8559
The volume is being formatted.
Recommended Action
Close the message box.
Please contact HP Technical Support.
Please contact HP Technical Support.
-
Please contact HP Technical Support.
Retry the operation with power ON.
Please contact HP Technical Support.
Please contact HP Technical Support.
You cannot execute the operation for the
volume which is not implemented.
Restore the blocked volume, then retry
the operation.
The system disk cannot be specified
as a P-VOL. Specify another volume.
Wait until the volume is formatted, and
retry the operation.
Check the target volume.
You cannot execute the operation for the
volume which is not implemented.
Restore the blocked volume, then retry
the operation.
The system disk cannot be specified
as an S-VOL. Specify another volume.
Wait until the volume is formatted, and
retry the operation.
A volume that is not used as a command
device must be specified as an S-VOL.
You cannot execute the operation for the
volume which is not implemented.
Restore the blocked volume, then retry
the operation.
The system disk cannot be specified
as a reserved volume. Specify another
volume.
Wait until the volume is formatted, and
retry the operation.
Severity
Level
i
E
E
i
E
W
E
E
W
E
W
W
W
W
W
W
W
W
W
Part code 7005 247

Advertisement

Table of Contents
loading

This manual is also suitable for:

P9000P9500

Table of Contents