Table 27 Error codes (part code 1005) (continued)
Part
Error
Code
Number
1005
1356
1005
1357
1005
1361
1005
1363
1005
1364
1005
1367
1005
1368
1005
1369
1005
1600
1005
1601
1005
1904
1005
1906
1005
1912
1005
1918
1005
1926
1005
1927
66
Message (part code group 1nnn)
Error Message
You could not add the host group to the
initiator or external port.
S-VOLs remain on the Fibre-RCU port.
This operation may cause a fatal
damage to the S-VOLs. Please stop this
operation. If you want to continue this
operation, please remove the S-VOLs
from the RCU port first.
No more user LUs can be set, because
the number of user LU settings has
reached the maximum.
You cannot add paths to journal
volumes.
The port type is incorrect.
The host mode "4C" is used for a host
group connecting to volumes that cannot
be used for External Storage.
The host mode "4C" can only be used
with External Storage volumes.
The specified host mode option cannot
be set to the initiator port.
This functionality is not available. Open
System Array Management is required.
This functionality is not available. Open
System Array Management is required.
The specified volume cannot be assigned
as an LUSE volume or a command
device, and the path of the volume
cannot be set because it is being used
as a Pool volume.
The specified volume cannot be set as a
command device because it is being
used as a V-VOL for Snapshot.
The specified volume is a remote
command device, and therefore the
command device setting or the command
device security setting cannot be set or
released.
An external volume is mapped to the
external port to be operated.
The path cannot be set to the specified
volume, because the volume is being
used as a quorum disk.
The specified volume cannot be set as a
command device, because it is being
used as a quorum disk.
Recommended Action
To add the host group, change the
attribute of the specified port to Target
or RCU Target.
The specified port is for Fibre Continuous
Access Synchronous. Delete a logical
path, then retry the operation.
Reduce the number of user LU settings,
then retry the operation.
Correct the settings, then retry the
operation.
Check the port type, then retry the
operation.
Check the settings, then retry.
Check the settings, then retry.
Verify the host mode option or the
attribute of the port.
Install the necessary program product
license key.
Install the necessary program product
license key.
Select another volume.
Select another volume.
Correct the settings, then retry the
operation.
Delete the external volume that is
mapped to the external port to be
operated, then retry the operation.
Check the setting.
Check the setting.
Severity
Level
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W