Table 47 Error codes (part code 05122) (continued)
Part
Error
Error Message
Code
Number
05122
1051 13
The real time graph display will end due
to changing the monitoring switch.
05122
1051 14
The CU to be monitored cannot be
added, because the number of CUs that
can be specified exceeds the maximum.
05122
1051 15
A WWN to be monitored cannot be
added, because the number of graph
display objects exceeds the maximum.
05122
1051 16
A WWN to be monitored cannot be
added, because the number of graph
display objects per one port exceeds the
maximum.
05122
105226
The Graph Display Term cannot be
changed, because there is no graph
data.
05122
105227
The HBA WWN is unedited.
05122
105228
The WWN Name is unedited.
05122
105229
No more WWN to be monitored can
be added, because the number of
monitoring WWNs has reached the
maximum.
05122
105230
There are no selectable parity groups.
05122
105247
The disk subsystem is in internal process,
or some other user is changing the
configuration. Wait, then retry the
operation.
05122
105254
No more graph items can be added
because the number of graph items that
can be displayed in one graph panel
has reached the maximum.
05122
107001
The processing cannot continue due to
aninternal logic contradiction.
05122
107002
The processing cannot continue due to
an internal logic contradiction.
05122
107003
The processing cannot continue due to
an internal logic contradiction.
Recommended Action
Retry the operation if you need the real
time graph display.
Reduce the number of CUs to be
monitored to 64 or fewer.
Reduce the number of WWNs to be
monitored to 2048 or fewer.
Reduce the number of WWNs to be
monitored to 32 or fewer per port.
Click [OK].
Edit the HBA WWN. If you do not edit
it, uncheck the check box.
Edit the WWN Name. If you do not edit
it, uncheck the check box.
Delete unnecessary monitoring WWNs,
then retry the operation.
Click [OK].
If the same problem occurs again, close
the windows, and retry the operation
after the internal processing or the
configuration change has been
completed. If the internal processing or
the configuration change takes much
time to complete, please contact HP
Technical Support.
Set the number of graph items per one
graph panel to 8 or less.
Refresh the window, then retry the
operation.
If the same problem persists despite
retrying, please contact HP Technical
Support.
Refresh the window, then retry the
operation.
If the same problem persists despite
retrying, please contact HP Technical
Support.
Refresh the window, then retry the
operation.
If the same problem persists despite
retrying, please contact HP Technical
Support.
Severity
Level
W
W
W
W
W
W
W
W
W
E
W
E
E
E
Part code 05122 127