Table 56 Error codes (part code 6505) (continued)
Part
Error
Code
Number
6505
8753
6505
8757
6505
8758
6505
8764
6505
8770
6505
8776
6505
8778
6505
8788
6505
8791
6505
8795
6505
8796
192 Message (part code group 6nnn)
Error Message
An internal error occurred.
One side of the cache or the shared
memory is blocked in the primary
storage system.
An unexpected error occurred in the
primary subsystem.
The secondary data volume is unusable,
or the emulation type of the secondary
data volume is not supported by
Continuous Access Journal or Continuous
Access Journal Z.
The cache in the primary subsystem is
automatically recovering.
The primary data volume is already used
by Compatible XRC.
One side of the cache or the shared
memory is blocked in the secondary
storage system.
The specified volume is not defined in
the secondary storage system.
The specified primary data volume is
online from hosts.
The operation failed because the
specified primary data volume was used
by Business Copy or Business Copy Z
and satisfied one of the following
conditions:
The volume was a Business Copy
S-VOL in non-PSUS status.
The volume was a Business Copy Z
T-VOL in non-Split status.
The volume was a reserved volume.
The volume was in the Reverse Copy
status.
The operation failed because the
specified secondary data volume was
one of the following:
An S-VOL or reserved volume of
Business Copy
A T-VOL or reserved volume of
Business Copy Z.
A T-VOL of Compatible FlashCopy.
Recommended Action
Check the SSB log, then contact HP
Technical Support.
Check the status of the cache and the
shared memory in the primary storage
system.
Ensure that the cache and shared
memory is not blocked.
Please contact HP Technical Support.
Check the SSB of the specified
secondary data volume. See the
OPENPLATFORM SECTION in the
maintenance manual to check whether
the device emulation type of the
secondary data volume is supported.
Click [OK] to finish processing. Then
wait a few minutes and retry the
operation.
Select another volume.
Check the status of the cache and the
shared memory in the secondary storage
system.
Ensure that the cache and shared
memory is not blocked.
Check the port, GID, and LUN settings
in the secondary storage system.
Vary the path offline from the other host,
then retry the operation.
Check the status of the primary data
volume from the host or the SVP.
Check the status of the secondary data
volume from the host or the SVP.
Severity
Level
E
E
E
W
W
W
E
W
W
W
W