Table 68 Error codes (part code 8105) (continued)
Part
Error
Error Message
Code
Number
8105
1353
S-VOLs remain on the Fibre-RCU port.
This operation may cause a fatal
damage to S-VOLs. Please stop this
operation. If you want to continue this
operation, please remove the S-VOLs
from the RCU port first.
8105
1354
Failed to add the WWN to the initiator
port.
8105
1355
The host mode of the host group
connected to the Initiator port cannot be
changed.
8105
1356
The host group cannot be added to the
Initiator port.
8105
1357
S-VOLs remain on the Fibre-RCU port.
This operation may cause a fatal
damage to the S-VOLs. Please stop this
operation. If you want to continue this
operation, please remove the S-VOLs
from the RCU port first.
8105
1364
The port type is incorrect.
8105
1369
The specified host mode option cannot
be set to the initiator port.
8105
1600
This functionality is not available. Open
System Array Management is required.
8105
1601
This functionality is not available. Open
System Array Management is required.
8105
1904
The specified volume cannot be assigned
as an LUSE volume or a command
device, and the path of the volume
cannot be set because it is being used
as a Pool volume.
8105
1906
The specified volume cannot be set as a
command device because it is being
used as a V-VOL for Snapshot.
8105
1910
The specified volume contains Snapshot
pairs.
8105
191 1
The specified volume contains Pool-VOLs.
8105
1912
The specified volume is a remote
command device, and therefore the
command device setting or the command
device security setting cannot be set or
released.
8105
1918
An external volume is mapped to the
external port to be operated.
Recommended Action
Since the port you are trying to set is for
Remote Copy, you must delete the S-VOL
logical path that is set to RCU Target,
then retry the port setting.
The port you are trying to set is for
Remote Copy. You must change the
attribute (Target or RCU Target) when
adding a WWN.
The port you are trying to set is for
Remote Copy. You must change the
attribute (Target or RCU Target) when
adding a WWN.
The port you are trying to set is for
Remote Copy. You must change the
attribute (Target or RCU Target) when
adding a host group.
The specified Port is for Fibre Continuous
Access Synchronous. Delete a logical
path, then retry the operation.
Check the port type, then retry the
operation.
Verify the host mode option or the
attribute of the port.
Install the necessary program product
licence key.
Install the necessary program product
licence key.
Select another volume.
Select another volume.
Select another volume.
Select another volume.
Correct the settings, then retry the
operation.
Delete the external volume that is
mapped to the external port to be
operated, then retry the operation.
Severity
Level
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
Part code 8105 287