HP XP P9500 Manual page 177

Hp p9000 remote web console messages (av400-96401, october 2011)
Hide thumbs Also See for XP P9500:
Table of Contents

Advertisement

Table 53 Error codes (part code 6005) (continued)
Part
Error
Error Message
Code
Number
that is specified as the R-VOL was being
initialized.
6005
68872
The operation failed, because the
specified volume was not a volume of
External Storage.
6005
68873
The operation failed, because the
specified volume was defined in the LU
path.
6005
68874
The operation failed, because the
emulation type of the specified volume
was not OPEN -V.
6005
68875
The operation failed, because the
specified volume was a LUSE volume.
6005
68876
The operation failed, because the parity
group of the specified external volume
was composed of two or more LDEVs.
6005
68877
The operation failed, because the
specified volume was a reserved
volume of Business Copy.
6005
68878
The operation failed, because the
specified volume was a journal volume.
6005
68879
The operation failed, because the
specified volume was a pool volume.
6005
68880
The operation failed, because the
specified volume was used for Auto
LUN.
6005
68881
The operation failed, because the
specified volume was used as a system
disk.
6005
68882
The operation failed, because the
quorum disk was inaccessible.
6005
68883
The operation failed, because the
specified serial number was different
from the serial number of the quorum
disk.
6005
68889
The operation failed, because the
quorum disk was blocked.
6005
68890
The operation failed, because the
specified serial number was not RCU
but MCU.
Recommended Action
Check the volume setting.
Specify another volume, or
release the LU path
definition.
Check the emulation type of
the volume.
Select another volume, or
release the LUSE setting.
Select a parity group of an
external volume that is
composed of a single LDEV.
Select another volume, or
release the Business Copy
setting.
Select another volume, or
release the journal volume
setting.
Select another volume, or
release the pool volume
setting.
Select another volume, or
release the Auto LUN setting.
Select another volume.
Check the following
conditions on the external
volume specified for the
quorum disk.
If it is blocked.
If a path is defined.
Check the serial number of
the quorum disk.
Check the status of the
quorum disk.
Specify the serial number of
RCU and retry the operation.
Severity Level
W
W
W
W
E
W
W
E
E
W
W
W
W
W
Part code 6005 177

Advertisement

Table of Contents
loading

This manual is also suitable for:

P9000P9500

Table of Contents