Table 31 Error codes (part code 2005) (continued)
Part
Error
Error Message
Code
Number
2005
1 137
Failed to form a LUSE volume because
the number of LUSE volumes exceeds the
maximum that can be set in a disk array
subsystem.
2005
1 138
The specified LDEV is already used for
another LUSE volume.
2005
1 182
The capacity of LUSE volume exceeds
the maximum.
2005
1 185
You are trying to insert in the linkage
operation including LUSE. (LDEV number
is inserted to the LDEV numbers created
in LUSE.)
2005
1 187
You cannot expand the LU because the
host mode of the group with paths which
are defined in the LU is corresponding
to online LUSE.
2005
1 196
The LUs cannot be combined or released
by mixing the internal and external LUs.
2005
1362
The LUSE volume cannot be configured
because the external volumes do not
have the same cache mode.
2005
1365
The different drive types cannot be
combined to form a LUSE volume.
2005
1599
This functionality is not available. Open
System Array Management is required.
2005
1600
This functionality is not available. Open
System Array Management is required.
2005
1601
This functionality is not available. Open
System Array Management is required.
2005
1904
The specified volume cannot be assigned
as an LUSE volume or a command
device, and the path of the volume
cannot be set because it is being used
as a Pool volume.
2005
1905
There are virtual volumes and non-virtual
volumes in the volumes specified to
compose a LUSE volume.
2005
1921
The specified volume is not a LUSE
volume.
2005
1922
LDEVs that are not normal are included
in the component of a LUSE volume.
2005
1923
The LDEVs to be combined are not
specified, or the number of LDEVs
exceeds the maximum number that can
be combined.
2005
1924
The all volumes that compose the LUSE
volume are not selected.
Recommended Action
The configuration information has been
changed already. Check the settings,
and request the configuration information
setting again.
Check the specified contents.
Check the setting.
The configuration information has been
changed already. Check the settings,
and request the configuration information
setting again.
The configuration information has been
changed already. Check the settings,
and request the configuration information
setting again.
Correct the specified content, then retry
the operation.
Check the attributes of the external
volumes, then retry the operation.
Confirm that the different drive types
(SAS drive, SATA drive, and flash drive)
don't coexist, then retry the operation.
Install the necessary program
productlicense key.
Install the necessary program
productlicense key.
Install the necessary program
productlicense key.
Select another volume.
Select another volume.
Check the volume, then retry the
operation.
Restore the LDEVs, then retry the
operation.
Check the setting.
Check the setting.
Severity
Level
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
Part code 2005